Willows Shopping Centre
- Expansion and site wide chilled water plant with large scale solar PV.
- D&C delivery.
- Master-planned the site over traditional isolated expansion.
- 10.2 MWr of Chiller capacity in master plan.
- 20KL low load Stratified TES.
- Master plan for future expansion.
- Centre achieved over 4.5 star NABERs exceeding expectations.
Reef HQ
- Centralised chilled water system with low lid.
- Thermal storage and micro grid control.
- Site energy savings of more than 60% and demand savings for more than 40%.
- Innovative approach to cooling Aquariums (public space and marine support life).
- 940 kWr of traditional Chiller capacity in master plan.
- 20KL low load Stratified TES.
- CO2 refrigeration rack on ice build and integration to site cooling.
- Microgrid control with large scale solar PV.
St Benedict’s School Townsville
- New secondary school achieving 5 star Greenstar rating.
- First school in NQ to achieve a 5 star greenstar design rating.
- Chilled water systems with preconditioned outdoor air and zone control ducted air conditioning plant.
Sunshine Coast University
- District cooling system with large scale stratified chilled water thermal energy storage and large scale solar PV system integration.
- BOOMT scheme.
- Principal services consultant for Mechanical, Electrical, Hydraulic and ESD.
- 8.5 MWr of Chiller capacity in master plan.
- 4 ML Stratified TES.
- Master plan for future expansion.
- Microgrid control with ~2.2MW of solar PV.
- Integration of HFO chillers and recycled water plant.
James Cook University Cairns
- District cooling system with large scale stratified chilled water thermal energy storage.
- 19.8 MWr of Cooling
- 9ML Stratified TES
- Approximately 7 KM under ground piping reticulation
- Master plan for future expansion
Australian Taxation Office Townsville
- NABERS and Greenstar Rated. New building and lead services consultants to achieve 4.5 star rating.
- D&C delivery with full engineering and workshop fabrication drawings.
- Principal services consultant for Mechanical, Electrical and ESD.
- 4.5 Star NABERS
- Enthalpy recovery systems with air cooled chillers and variable air volume systems.
University of Queensland Gatton
- 10.7 MWr of Chiller capacity in master plan.
- 3 ML Stratified TES
- Approximately 2.7 KM underground piping reticulation.
- Master plan for future expansion
- Microgrid control with ~5.4MW of solar PV.
James Cook University Townsville
- District cooling system with large scale stratified chilled water thermal energy storage.
- 20.8 MWr of Chiller capacity in master plan.
- 12ML Stratified TES
- Approximately 8.7 KM under ground piping reticulation.
- Approximately 34 connected buildings.
- Master plan for future expansion
- Largest known system in Australia when constructed and possibly still today